| 1 |
| |
|
| |
| |
|
ESCORT Series On Line Uninterruptible Power System |
The Escort-series is true on line double conversion topology, high efficiency operation, true isolation, input power factor correction and superior output voltage regulation. The Escort series has a wide input range mains voltage from 165v ~ 272v (220v), 90v ~ 132v (110v) against heavy discharges ensuring that batteries are reversed for emergency conditions. It provides regulated output for the fileservers, workstations and for all of emergency products to be powered.
|
| |
• |
True on line sinewave UPS |
• |
DC voltage power on available |
• |
Neutral isolation design |
• |
Overload & output short protection |
• |
High input power factor ≥0.97 |
• |
External battery pack available |
• |
Full bridge inverter |
|
|
|
|
|
|
| |
|
|
| |
Three Phase LUP Series Technology Specifications. |
|
| |
Model |
LUF-1000 |
LUF-1500 |
LUF-2000 |
LUF-3000 |
Capacity |
1 KVA |
1.5 KVA |
2 KVA |
3 KVA |
Input |
Voltage |
165V~272V(230V), 90V~140V(115V) |
Frequency |
50 or 60 Hz ±5% |
Phase |
>0.97 |
Output |
Voltage |
115V or 208V, 230V |
Phase |
1ø2W+G |
Voltage Regulation |
±1% at linear load |
Frequency |
50 or 60 Hz ±5% |
Power Factor |
0.7 |
Waveform Distortion |
Pure sinewave less than 3% at full load |
Crest Factor |
3 : 1 |
Overload Capacity |
100% continuous, 150% for 25 seconds |
Efficiency AC to AC |
>80% at battery fully charge |
Battery |
Type |
12V 7AH 3 pcs |
12V 7AH 4 pcs |
12V 7AH 8 pcs |
12V 34AH 8 pcs |
Back up Time |
Computer load 15~30 min. |
Recharge Time |
4~8 hours 90% after fully discharge |
Transfer Time |
Bypass to UPS |
No break |
UPS to Bypass |
< 2 ms |
Indicator |
Multi function LED Display |
Line, Inverter, Bypass, Fault, Battery/ Load level |
Audible Alarm |
1) AC Failure |
Sound every 4 seconds after line fails |
2) Battery Low |
Sound every second when approaches battery low level |
3) UPS Fault |
Continuous alarm |
Protection |
Over/under voltage at I/P |
Yes |
Short Circuit & overload |
The UPS shuts down and will not transfer to the bypass mode when a
short circuit occurs on the output of the unit. After the short circuit being
removed the UPS will operate normally again. At short condition, the
Fault LED lights as a warning to end users. |
| |
Lighting: Yes. Surge: Yes. |
Environment |
Temperature |
0°C to 40°C |
Humidity |
0°C to 90°C at non condensing |
Noise Level |
<45dB at 1 meter |
Connection |
Interface Port |
DB-9 connector (option) |
Dimension |
WxDxH (mm) |
145 x 240 x 480 |
145 x 310 x 480 |
210 x 430 x 550 |
210 x 430 x 550 |
Weight |
Net Weight |
18 kgs |
28 kgs |
43 kgs |
50 kgs |
|
|
| |
|
|
| |
|
|
| |
Single Phase LUV Series Technology Specifications. |
|
| |
Model |
LUV-50 |
LUV-60 |
LUV-80 |
LUV-100 |
LUV-150 |
LUV-200 |
LUV-300 |
Capacity |
5KVA |
6KVA |
8KVA |
10KVA |
15KVA |
20KVA |
30KVA |
Input (Rectifier) |
Voltage |
110V or 220V ± 15% |
Frequency |
50 or 60 Hz ± 5% |
Phase |
1ø2W+G or 3ø3W+G, 3ø4W+G |
Output (inverter) |
Voltage |
115V or 208V, 230V |
Phase |
1ø2W+G or 1ø3W+G (option) |
Voltage Regulation |
± 1% at linear load |
Frequency |
50Hz or 60Hz ± 0.5% |
Power Factor |
0.8 |
Waveform Distortion |
Less than 3% at linear load |
Crest Factor |
3 : 1 |
Overload Capacity |
100% continuous, 150% for 25 seconds |
Efficiency AC to AC |
>85% at battery fully charge |
Battery |
Voltage |
192V (12V x 16pcs) |
240V |
Back up Time |
Computer load 15~30 min. |
Recharge Time |
4~8 hours 90% after fully discharge |
Transfer Time |
Mains <> Inverter |
No break |
Indicator |
LCD Display |
Input/Output voltage, Frequency, Output current percentage,
Battery voltage, Operating temperature. |
LED Display |
Mimic display |
Audible Alarm |
Battery Discharge |
Sound every 4 seconds. Sound every 1 second for battery low. |
UPS Fault |
Continuous sound |
Protection |
Output Short |
Yes |
Lightning |
Yes |
Environment |
Temperature |
0°C to 40°C |
Humidity |
0 to 90%, non condensing |
Noise Level |
< 50dB at 1 meter |
< 60dB at 1 meter |
Communication |
Interface Port |
RS-232 or AS-400 |
Dimension
(WxHxD) (mm) |
UPS |
260 x 800 x 660 |
260 x 900 x 660 |
310 x 900 x 660 |
360 x 740 x 870 |
Battery Bank |
360 x 740 x 870 |
Net Weight |
UPS |
130kgs |
160kgs |
190kgs |
320kgs |
190kgs |
230kgs |
280kgs |
Battery Bank |
200kgs |
200kgs |
290kgs |
|
|
| |
|
|
| |
|
|
|
| |
|
| |
|
| |
|