| 1 |
| |
|
| |
| |
|
LUP & LUV Series True On Line Uninterruptible Power System |
• |
Input true galvanic isolation transformer
Con Solve Ultimately the problem of power system, including leakage current, noise interference... etc.
|
• |
Per phase with individual inverter support
Characteristics will not be violated under 100% unbalance load. |
• |
DC start available
Can be started without AC power source.
|
• |
12 pulse full controlled rectifier (option)
Can reduce harmonic current.
|
• |
Advanced battery management
Battery replacement warning prevents downtime.
|
|
|
|
| |
|
|
| |
Three Phase LUP Series Technology Specifications. |
|
| |
Model |
LUP-15 |
LUP-20 |
LUP-30 |
LUP-40 |
LUP-50 |
LUP-60 |
LUP-80 |
LUP-100 |
Capacity |
15KVA |
20KVA |
30KVA |
40KVA |
50KVA |
60KVA |
80KVA |
100KVA |
Input (Rectifier) |
Voltage |
3ø 380V/ 400V/ 415V ± 15% + N* |
Frequency |
50 or 60 Hz ± 5% |
Power Walk-in |
0 ~ 100% : 10 sec. |
Output (inverter) |
Voltage |
3ø 380V/ 400V/ 415V + N* |
Frequency |
50 or 60 Hz ± 0.5% |
Static Regulation |
± 1% at linear load |
Dynamic Regulation |
≤ 2% at 50% load unbalance, ≤ 5% at 100% load unbalance |
THD Distortion |
≤ 3% at linear load, ≤ 5% at Non-linear load |
Transient Response |
< 5ms |
Power Factor |
0.8 |
Overload Capacity |
100% continuous, 125% for 10 minutes, 150% for 1 minute |
Battery |
Voltage |
192V (12V x 16pcs) |
348V (12V x 29pcs) |
Maximum Charge
Current |
5A |
10A |
Float Voltage |
216V |
392V |
Boost Voltage |
230V |
420V |
Recharge Time |
4~8 hours 90% after fully discharge |
Static Switch |
Mains <> Inverter |
No break |
Indicator |
LCD Display |
As left showing |
LED Display |
Mimic display |
Protection |
Output Short |
Yes |
Lightning/EMI Filter |
Yes |
Environment |
Temperature |
0°C to 40°C |
Humidity |
0 to 90%, non condensing |
Noise Level |
< 60dB at 1 meter |
< 65dB at 1 meter |
Communication |
Interface Port |
RS-232 or AS-400 (standard), SNMP adaptor, RS-485 (option) |
Dimension
(WxHxD) (mm) |
UPS |
660 x 1550 x 800 |
660 x 1550 x 800 |
1100 x 1710 x 850 |
Battery Bank |
660 x 1550 x 800 |
660 x 1550 x 800 |
Net Weight |
UPS |
250kgs |
300kgs |
400kgs |
500kgs |
200kgs |
250kgs |
300kgs |
450kgs |
Battery Bank |
430kgs |
500kgs |
630kgs |
1100kgs |
|
|
| |
|
|
| |
|
|
| |
Single Phase LUV Series Technology Specifications. |
|
| |
Model |
LUV-50 |
LUV-60 |
LUV-80 |
LUV-100 |
LUV-150 |
LUV-200 |
LUV-300 |
Capacity |
5KVA |
6KVA |
8KVA |
10KVA |
15KVA |
20KVA |
30KVA |
Input (Rectifier) |
Voltage |
110V or 220V ± 15% |
Frequency |
50 or 60 Hz ± 5% |
Phase |
1ø2W+G or 3ø3W+G, 3ø4W+G |
Output (inverter) |
Voltage |
115V or 208V, 230V |
Phase |
1ø2W+G or 1ø3W+G (option) |
Voltage Regulation |
± 1% at linear load |
Frequency |
50Hz or 60Hz ± 0.5% |
Power Factor |
0.8 |
Waveform Distortion |
Less than 3% at linear load |
Crest Factor |
3 : 1 |
Overload Capacity |
100% continuous, 150% for 25 seconds |
Efficiency AC to AC |
>85% at battery fully charge |
Battery |
Voltage |
192V (12V x 16pcs) |
240V |
Back up Time |
Computer load 15~30 min. |
Recharge Time |
4~8 hours 90% after fully discharge |
Transfer Time |
Mains <> Inverter |
No break |
Indicator |
LCD Display |
Input/Output voltage, Frequency, Output current percentage,
Battery voltage, Operating temperature. |
LED Display |
Mimic display |
Audible Alarm |
Battery Discharge |
Sound every 4 seconds. Sound every 1 second for battery low. |
UPS Fault |
Continuous sound |
Protection |
Output Short |
Yes |
Lightning |
Yes |
Environment |
Temperature |
0°C to 40°C |
Humidity |
0 to 90%, non condensing |
Noise Level |
< 50dB at 1 meter |
< 60dB at 1 meter |
Communication |
Interface Port |
RS-232 or AS-400 |
Dimension
(WxHxD) (mm) |
UPS |
260 x 800 x 660 |
260 x 900 x 660 |
310 x 900 x 660 |
360 x 740 x 870 |
Battery Bank |
360 x 740 x 870 |
Net Weight |
UPS |
130kgs |
160kgs |
190kgs |
320kgs |
190kgs |
230kgs |
280kgs |
Battery Bank |
200kgs |
200kgs |
290kgs |
|
|
| |
|
|
| |
|
|
|
| |
|
| |
|
| |
|